TOTAL HYDROCARBON ANALYSIS

Laboratory Gas Analysis Services

Detect Hydrocarbon Contamination in Gas Systems

One of Singapore’s leading providers of total hydrocarbon analysis services for compressed air and gas distribution systems – identifying CO, CO₂, CH₄, H₂, and oil mist contamination that compromises product quality and equipment performance.

Detect hydrocarbon contamination at trace levels Analyze CO, CO₂, CH₄, H₂, and oil mist Comprehensive analysis reports for compliance

THE PROBLEM YOU'RE SOLVING

Hydrocarbon Contamination Threatens Product Quality

Hidden Contamination

Compressor oil carryover, ambient air pollutants, and system contamination introduce hydrocarbons into compressed air and gas distribution systems. These contaminants cause product defects, and process failures.

Compliance Requirements

Semiconductor industries require documented proof that compressed air and other gas systmes meets purity specifications. Hydrocarbon contamination exceeding limits risks product recalls.

The Solution

Total hydrocarbon analysis identifies and quantifies CO, CO₂, CH₄, H₂, and oil mist contamination through laboratory testing. Sample-based analysis provides accurate, documented results for quality assurance and regulatory compliance.

WHAT IS TOTAL HYDROCARBON ANALYSIS?

Laboratory Analysis for Compressed Air and Gas Purity

Total hydrocarbon analysis is laboratory testing that identifies and quantifies hydrocarbon contamination in compressed air and other gas samples. This analytical method detects carbon monoxide, carbon dioxide, methane, hydrogen, and oil mist at trace levels, verifying system purity and compliance with industry standards.

Why Total Hydrocarbon Analysis Matters

Compressed Air Quality Verification

Confirms compressed air meets ISO 8573 purity standards for manufacturing applications.

Oil-Free Verification

Verifies oil-free compressor performance and detects unexpected oil contamination. Critical for semiconductor and electronics manufacturing.

Product Quality Protection

Prevents hydrocarbon contamination from reaching sensitive manufacturing processes. Protects electronics, and final products from defects.

SAMPLE COLLECTION & ANALYSIS PROCESS

Simple Sample Collection, Professional Laboratory Analysis

Total hydrocarbon analysis is laboratory testing that identifies and quantifies hydrocarbon contamination in compressed air and other gas samples. This analytical method detects carbon monoxide, carbon dioxide, methane, hydrogen, and oil mist at trace levels, verifying system purity and compliance with industry standards.

What's Included in Your Report:

Sample identification and collection details

Comparison to ISO 8573 or specified limits

Pass/fail determination per acceptance criteria

STEP 1: SAMPLE COLLECTION CONSULTATION

  • We provide sample collection instructions and procedures
  • Specify sampling locations and techniques
  • Supply sample collection cylinders (if required)
  • Coordinate sampling timing and conditions
  • Review system specifications and requirements

Pre-sampling consultation

Review procedures, prepare sampling equipment

STEP 2: CLIENT SAMPLE COLLECTION

  • Client collects samples following client’s procedures
  • Sample collection at specified system locations
  • Documentation of sampling conditions and parameters
  • Proper sample container preparation and labeling

Per your schedule

Collect samples per instructions, document conditions

STEP 3: SAMPLE SUBMISSION

  • Submit collected samples to third-party laboratories
  • Provide system specifications and analysis requirements
  • Specify acceptance criteria
  • Confirm turnaround time requirements

After sample collection

Deliver samples with documentation

STEP 4: LABORATORY ANALYSIS

  • Laboratory receives and logs samples
  • Samples are analyzed using appropriate analytical methods
  • Quality control procedures are followed
  • Results are reviewed and validated

Varies by analysis scope (typically 10 to 14 business days)

None (analysis in progress)

STEP 5: RESULTS & REPORTING

  • Comprehensive analysis report is generated
  • Results are compared against acceptance criteria
  • Hard copy reports are delivered

 

Report delivered per agreed turnaround time

Review results, implement recommendations if needed

INDUSTRIES & APPLICATIONS

Critical Analysis Across Quality-Sensitive Industries

Hydrocarbon testing for industries where contamination causes product failures

Semiconductor Manufacturing

Why Hydrocarbon Analysis Matters: Semiconductor processes require ultra-pure gases and compressed air. Hydrocarbon contamination causes wafer defects, contamination excursions, and yield losses.

Critical Applications:

  • Compressed air systems: Verify air for tool pneumatics meets specifications
  • Nitrogen purity: Confirm bulk nitrogen is free from hydrocarbon contamination
  • Process gas quality: Verify specialty gas delivery system purity


Testing Standards Met:

  • ISO 8573
  • Client-specific contamination limits

WHEN YOU NEED TRACE GAS ANALYSIS

Critical Testing Scenarios for Air Quality Verification

Schedule hydrocarbon analysis at these key milestones to verify system purity

New Facility Commissioning

Verify compressed air and gas systems meet purity specifications before production startup.

Compressor Installation

Confirm new or rebuilt compressors deliver oil-free air per specifications. Verify oil removal filtration effectiveness.

FREQUENTLY ASKED QUESTIONS

Hydrocarbon Analysis FAQs

How do I collect samples for analysis?

We provide detailed sample collection instructions and procedures. Sample collection performed by your personnel following our specified methods to ensure sample integrity. Sample collection cylinders can be supplied if needed.

Sample volume requirements depend on analysis scope and analytes requested. Typical compressed air samples: 1-5 liters collected in appropriate sample containers. Specific requirements provided during consultation.

Standard turnaround time: 10 to 14 days business days after sample receipt. Rush analysis available for urgent needs. Turnaround time varies by analysis scope and complexity.

For compressed air: ISO 8573 Class specifications (oil, typically Class 1-5).

Yes. We analyze bulk process gases for hydrocarbon contamination. Analysis scope customized to your specific gas types and applications.

Yes. Every analysis includes comprehensive documentation: detailed results reports, laboratory certifications, and compliance statements. All documentation is audit-ready for regulatory submissions.

Yes. Laboratory analysis conducted at accredited facilities with appropriate quality certifications.

CALL-TO-ACTION

Verify Your Compressed Air and Gas Purity Now

Hydrocarbon contamination is invisible until quality failures occur – test your systems today.

Privacy note: Your information is confidential and will only be used to provide you with a testing quote.

“To maintain our position as leader in the QA and QC industry and to continually provide excellent customer experience through rigorous adherence to superior quality standards”

Blk 4009 Ang Mo Kio Ave 10 #03-32 Techplace 1 Singapore 569738

Let your Data Tell a Story

Only a team who understands every word and faces of your clients can provide you fruitful insights.